  • Lightning arrester
Lightning arrester
+

Lightning arrester

Surge arresters are the foundation of the insulation coordination of various electrical equipment in power systems (transformers, reactors, capacitors, generators, motors, PTs, CTs, circuit breakers, contactors, and all other medium and high-voltage electrical equipment). The protection performance of surge arresters determines the internal and external insulation indicators (short-time power frequency withstand voltage, lightning impulse withstand voltage, and switching impulse withstand voltage, etc.) of all electrical equipment in the power system. Metal Oxide surge Arresters (MOA) are advanced products among conventional surge arresters. The core working element uses zinc oxide-based multi-metal oxide powder sintering, which has excellent non-linear volt-ampere characteristics, fast steep wave response, and large current carrying capacity.
  • Commodity name: Lightning arrester

Product Details

Overview

Surge arresters are the foundation of the insulation coordination of various electrical equipment in power systems (transformers, reactors, capacitors, generators, motors, PTs, CTs, circuit breakers, contactors, and all other medium and high-voltage electrical equipment). The protection performance of surge arresters determines the internal and external insulation indicators (short-time power frequency withstand voltage, lightning impulse withstand voltage, and operating impulse withstand voltage, etc.) of all electrical equipment in the power system. Metal Oxide surge Arrester (hereinafter referred to as MOA) is an advanced product among conventional surge arresters. The core working element uses a multi-element metal oxide powder mainly made of zinc oxide, which has excellent nonlinear voltage-current characteristics, fast steep-wave response, and large current carrying capacity.

Model Description

Technical Parameters

Table 1 Electrical Characteristics of Conventional Surge Arresters 10kV and Below

Application Scenarios System Nominal Voltage (kV) Arrester Model Arrester Rated Voltage (kV) Arrester Continuous Operating Voltage (kV) DC 1mA Reference Voltage (kV) ≥ Leakage Current at 0.75 DC Reference Voltage (μA) ≤ 8/20 Lightning Impulse Residual Voltage (kV) ≤ 30/60 Operating Impulse Residual Voltage (kV) ≤ 1/4 Steep-wave Impulse Residual Voltage (kV) ≤ 2000μs Square Wave Current Carrying Capacity (A)
Low Voltage 0.22 Y(H)1.5W-0.28/1.3 0.28 0.24 0.6 50 1.3 - - 75
0.38 Y(H)1.5W-0.5/2.6 0.5 0.42 1.5 50 2.6 - - 75
Distribution 3 Y(H)5WS-5(3.8)/15 5(3.8) 4.0(2.0) 7.5 50 15.0 12.8 17.3 75
6 Y(H)5WS-10(7.6)/30 10(7.6) 8.0(4.0) 15.0 50 30.0 25.6 34.6 75
10 Y(H)5WS-17(12.7)/50 17(12.7) 13.6(6.6) 25.0 50 50.0 42.5 57.5 75
Power Station 3 Y(H)5WZ-5(3.8)/13.5 5(3.8) 4.0(2.0) 7.2 50 13.5 11.5 15.5 200
6 Y(H)5WZ-10(7.6)/27 10(7.6) 8.0(4.0) 14.4 50 27.0 23.0 31.0 200
10 Y(H)5WZ-17(12.7)/45 17(12.7) 13.6(6.6) 24.0 50 45.0 38.0 51.8 200
Capacitor 3.15 Y(H)5WR-5(3.8)/13.5 5(3.8) 4.0(2.0) 7.2 50 13.5 10.5 - 400
6.3 Y(H)5WR-10(7.6)/27 10(7.6) 8.0(4.0) 14.4 50 27.0 21.0 - 400
10.5 Y(H)5WR-17(12.7)/46 17(12.7) 13.6(6.6) 24.0 50 46.0 35.0 - 400
Motor 3.15 Y(H)2.5WD-4(3.8)/9.5 4(3.8) 3.15(2.0) 5.7 50 9.5 7.6 10.7 400
6.3 Y(H)2.5WD-8(7.6)/18.7 8(7.6) 6.3(4.0) 11.2 50 18.7 15.0 21.0 200
10.5 Y(H)2.5WD-13.5(12.7)/31 13.5(12.7) 10.5(6.6) 18.6 50 31.0 25.0 34.7 200
Generator 3.15 Y(H)5WD-4(3.8)/9.5 4(3.8) 3.15(2.0) 5.7 50 9.5 7.6 10.7 400
6.3 Y(H)5WD-8(7.6)/18.7 8(7.6) 6.3(4.0) 11.2 50 18.7 15.0 21.0 400
10.5 Y(H)5WD-13.5(12.7)/31 13.5(12.7) 10.5(6.6) 18.6 50 31.0 25.0 34.7 400
13.8 Y(H)5WD-17.5/40 17.5 13.8 24.4 50 40.0 32.0 44.8 400
15.75 Y(H)5WD-20/45 20 15.75 28 50 45.0 36.0 50.4 400
18.0 Y(H)5WD-23/51 23.0 18.0 31.9 50 51.0 40.8 57.0 400
20.0 Y(H)5WD-25/56.2 25.0 20.0 25.4 50 56.2 45.0 62.9 400

Table 2 Electrical Characteristics of Conventional Surge Arresters 35kV and Above

System Nominal Voltage (kV) Application Scenarios Arrester Model Arrester Rated Voltage (kV) Arrester Continuous Operating Voltage (kV) DC 1mA Reference Voltage (kV) ≥ Leakage Current at 0.75 DC Reference Voltage (μA) ≤ 8/20μs Impulse Current Residual Voltage (kV, Peak) ≤ 30/60μs Operating Impulse Current Residual Voltage (kV, Peak) ≤ 1/4 Steep-wave Impulse Current Residual Voltage (kV, Peak) ≤ 2000μs Square Wave Current Carrying Capacity (A)
35 Power Station Y(H)5WZ-51(42)/134 51(42) 40.8(23.4) 73 50 134 114 154 400
Capacitor Y(H)5WR-51(42)/134 51(42) 40.8(23.4) 73 50 134 105 - 400
Line Y(H)5WX-51(42)/134 51(42) 40.8(23.4) 73 50 134 114 154 400
  YHSWX-54/150 54(42) 40.8 77 50 150 128 169 400
Line Suspension Type HY5CX-42/120 42 70.0 240 - 120 - 138 400
66 Power Station Y(H)5WZ-84/221 84 67.2 121 50 221 188 254 600
Y(H)5WZ-90/235 90 72.5 130 50 235 201 270 600
Y(H)10WZ-84/221 84 67.2 121 50 221 188 248 600
Y(H)10WZ-90/235 90 72.5 130 50 235 201 264 600
Line YHSWX-96/250 96 75 140 50 250 213 288 600
YHSWX-96/275 96 75 154 50 275 234 316 600
110 Power Station Y(H)5WZ-100/260 100 78 145 50 260 221 399 600
Y(H)5WZ-102/266 102 79.6 148 50 266 226 305 600
Y(H)5WZ-108/281 108 84 157 50 281 239 323 600
Y(H)10WZ-100/260 100 78 145 50 260 221 291 600
Y(H)10WZ-102/266 102 79.6 148 50 266 226 297 600
Y(H)10WZ-108/281 108 84 157 50 281 239 315 600
Line YHSWX-108/281 108 84 157 50 281 239 323 600
YHSWX-108/309 108 84 173 50 309 263 348 600
YH10WX-108/281 108 84 157 50 281 239 315 600
YH10WX-108/309 108 84 173 50 309 263 348 600
220 Power Station Y(H)10WZ-192/500 192 150 280 50 500 426 560 600

Table 3 Electrical Characteristics Table of Conventional Neutral Point Arrester

Application Scenarios System Nominal Voltage (kV) Arrester Model Arrester Rated Voltage (kV) Arrester Continuous Operating Voltage (kV) DC 1mA Reference Voltage (kV) ≥ Leakage Current at 0.75 DC Reference Voltage (μA) ≤ 8/20μs Lightning Impulse Current Residual Voltage (kV, Peak) ≤ 30/60μs Operating Impulse Current Residual Voltage (kV, Peak) ≤ 2000μs Square Wave Current Carrying Capacity (A)
Motor 3.15 Y(H)1.5W-2.4/6 2.4 1.9 3.4 50 6.0 5.0 400
6.3 Y(H)1.5W-4.5/12 4.8 3.8 6.8 50 12.0 10.0 400
10.5 Y(H)1.5W-8/19 8.0 6.4 11.4 50 19.0 15.9 400
13.8 Y(H)1.5W-10.5/23 10.5 8.4 14.9 50 23.0 19.2 400
15.75 Y(H)1.5W-12/26 12 9.6 17.0 50 26.0 21.6 400
18.0 Y(H)1.5W-13.7/29.2 13.7 11.0 19.5 50 29.2 24.3 400
20.0 Y(H)1.5W-15.2/31.7 15.2 12.2 21.6 50 21.7 26.4 400
Transformer 35 Y(H)1.5W-30/80 30 24 44 50 80 67.5 400
110 Y(H)1.5W-60/144 60 48 85 50 144 135 400
110 Y(H)1.5W-72/186 72 58 103 50 186 174 400
220 Y(H)1.5W-144/320 144 116 205 50 320 299 400
330 Y(H)1.5W-207/440 207 167 208 50 440 411 400

Keywords

Four core advantages

Xin Aochuang

Excellent raw material

Testing materials complete quality assurance

Xin Aochuang

Experienced

Technical precision, fast delivery, professional production

Xin Aochuang

Strength Factory

years of professional production source factory

Xin Aochuang

Support customization

Customize drawings and samples on demand

Testing equipment

Plant environment
Plant environment
Production Equipment
Production Equipment
Production Line
Production Line
Production Environment
Production Environment

FAQ

We have collected some frequently asked questions to help you better understand our company, our capabilities, our products and services.

Can I have my own custom product?


Yes. oem and odm can be provided, including design, logo, packaging, etc.

What is the minimum order quantity?


It depends on the product.

What are the terms of payment?


Wire transfer or letter of credit, Western Union, Alipay, etc.

When is the delivery time?


Inventory orders within 7-15 days, for oem and odm orders, the specific time depends on the actual situation

Can I take samples for testing?


Yes, samples can be sent for testing before bulk ordering.

Do you have pre-shipment inspection procedures?


Yes, we always test the products before delivery.

Leave Us A Message

*Note: Please fill in the information accurately and keep the communication open. We will contact you as soon as possible.

Submit